Preparatory Work Before eto Sterilization
Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.
Preparatory Work Before eto Sterilization Read more
Appearance Inspection: Check the main unit, control rack, and electrical control cabinet for any damage on the surface.
Preparatory Work Before eto Sterilization Read more
Start cycle phase(Select parameters/sterilization recipe) Serial number Potentially risky content Risk assessment under existing process conditions Risk assessment of the
EO sterilization equipment and process characteristic patterns and effect analysis Read more
9.1 During ETO Sterilization, operators are not allowed to leave the operating area and must continuously observe the ETO Sterilization process. If any abnormal phenomena occur, the machine must be immediately shut down, and the power supply should be cut off for inspection.
Maintenance Guide for ETO Sterilizers Read more
For the purposes of this document, the following terms and definitions apply in ethylene oxide sterilization 3.1 Aeration part of
Terms and definitions of eto gas sterilization Read more
Appearance Inspection: Check for any damage on the surfaces of the main machine, control rack, and electrical control cabinet.
Power Supply Check: Ensure the power supply meets the requirements and check the rotation direction of the water pump and vacuum pump.
Turn on the power and observe whether the instrument display values are normal; otherwise, cut off the power, inspect and repair before restarting.
Pipeline Inspection: Check for leaks in the water supply, vacuum, and medication delivery pipelines, and ensure all valves are in standby mode; adjust if necessary.
Preparation Work Before eo Sterilization Read more
2.1.1 The overall shape should be precise, with smooth, clean surfaces and uniform color. There should be no burrs, sharp edges, cracks, visible scratches, or unevenness.
2.1.2 All external text, graphics, and symbols must be printed clearly, with precise and durable markings.
2.1.3 Fasteners must be securely installed. All control switches and adjustment knobs (or buttons) should operate smoothly and reliably without obstructions.
Request For Eto Gas Sterilizer Manufacturer Read more
Within a certain range of gas concentration, the higher the concentration, the better theEO Gas Sterilization effect; beyond 1000 mg/L, the improvement in sterilization effect is not significant.
Factors Affecting the EO Gas Sterilization Process Read more
eto sterilization technologies vs others: Advantages and Disadvantages Sterilization is a critical process in infection control, ensuring that medical instruments
Comparing ETO Sterilization to Other Methods Read more
The temperature setting range of the ETO Sterilization Chamber should be between 30-60°C. It is recommended to perform temperature distribution testing of the sterilizer’s internal surface and temperature and humidity distribution testing inside the sterilization chamber to ensure the effectiveness of the heating and humidifying systems.
ETO Sterilization Chamber Testing Read more
The purpose of routine monitoring and control of EO (Ethylene Oxide) sterilization is to demonstrate that the confirmed and specified sterilization process has been applied to the product. Data from each sterilization cycle should be recorded and retained to prove that the confirmed sterilization process specifications have been met. This should include at least the following content:
Routine Monitoring, Control, and Release of Ethylene Oxide Sterilization Read more